Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator

Product Details
Customization: Available
Type: Ion Air Nozzle
Transport Package: Carton Box
Still deciding? Get samples of US$ 80/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
24
Year of Establishment
2006-09-30
  • Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator
  • Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator
  • Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator
  • Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator
  • Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator
  • Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator
Find Similar Products

Basic Info.

Model NO.
KP2001B-7T
Specification
95(L)*57(W)*28(H)mm
Trademark
KAPPER
Origin
China
HS Code
8414599099
Production Capacity
50000PCS/Year

Product Description

SECTION 1:DESCRIPTION***********************************************************
KP2001A-7T High-frequency ioninzing air nozzle is a fixed static elimination device developed and produced by Capal Company to eliminate static electricity and dust on the surface of objects. It can be used only with compressed air.
KP2001A-7T High-frequency ioninzing air nozzle adopts current international new technology, adopts a small high-voltage electric transformer, and converts the input direct current into high-frequency and low-voltage alternating current. There are no external high-voltage components and high-voltage wiring, and different components can be easily added. On different occasions.
KP2001A-7T High-frequency ioninzing air nozzle can generate a large amount of positive and negative charge air flow, which is blown out by the compressed air at high speed, which can neutralize the charge on the object. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. The purpose of static electricity.
KP2001A-7T High frequency ioninzing air nozzle is widely used in industries such as mechanical equipment, medical equipment manufacturing, electronic assembly, semiconductor manufacturing and so on.

SECTION 2:FEATURES***************************************************************
1.The generated ion density is high, and the static electricity removal speed is fast.
2.The ion airflow covers a large area.
3.Small size, light weight, easy to install.
4.With indicator light alarm function.
5.The air nozzle has a straight-front outlet with a tube, a side outlet with a tube, a straight-front outlet with an elbow, and a straight outlet without a tube.
6.The air nozzle has a good grounding protection function.


SECTION 3:SPECIFICATIONS********************************************************
Working voltage DC24V
Air supply connetor Ф8mm(Customized length)
Ion balance ≤|±15V|(Distance from the wind mouth 300mm)
Discharge time   ≤1S(Distance from the wind mouth 300mm)
Use medium Clean compressed air
Working temperature 0ºC-50ºC
Working humidity <75%
Power cord length 1.2M(Customized length)
Compressed air pressure 0.3-0.8Mpa
Airflow volocity 3-10m/
Nose ≤65dB
Ozone concentration ≤ 0.03 ppm  (Distance from the wind mouth 150mm)
Dimension 95mm(L)*68.5mm(W)*28mm(H)
Gross weight 0.4kg(included accessories)

SECTION 4:TEST  RESULT**********************************************************
Testing condition
Humidity:≤60%       Testing voltage:1KV-100V     Temperature:22ºC
Distance 300mm 600mm
Decay time Positive 0.7s 1.3s
Negative 0.8s 1.4s
Offset voltage Positive |±15V|
Negative
* The test result by ME268A comprehensive electrostatic tester shall prevail.
* Test according to IEC - 61340-5-1 A 6.
* Test data may change with the surrounding temperature and humidity.

SECTION 5:APPLICATION*************************************************************
Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator

SECTION 6:KAPPER NEW FACTORY***********************************************
Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator
SECTION 7:CERTIFICATES*********************************************************
Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator
SECTION 8:KAPPER STYLE

Kapper Industrial Anti Static Anti Dust High Frequency Ionizing Air Nozzle Electrostatic Eliminator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier