Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower

Product Details
Customization: Available
Certification: GS, RoHS, ISO, CE
Usage: SMT Production Line, Printing Workshop, Computer Room, Electronic Component Maintenance Room, Combustible & Explosive Area
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
24
Year of Establishment
2006-09-30
  • Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
  • Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
  • Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
  • Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
  • Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
  • Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
Find Similar Products

Basic Info.

Model NO.
KP3008C-7T
Condition
New
Waterproof
Non-Waterproof
Type
Ionizing Air Blower
Material
Metal
Transport Package
Carton Box
Specification
163(L)*126(W)*700(H)mm
Trademark
KAPPER
Origin
China
HS Code
8414599099
Production Capacity
50000PCS/Year

Product Description

SECTION 1:DESCRIPTION***********************************************************
KP3008C-7T  3th generation ionizing air snake snake is an antistatic device developed and produced by Kapper Company to eliminate static electricity on the surface of objects.
KP3008C-7T  3th generation ionizing air snake is a sitting-and-standing static eliminator, which can manually deform the snake tube to make the wind snake point to the target direction, and let the ion air flow directly blow to the target surface, which is convenient for movement. It can be placed in various working areas to eliminate static electricity. The dust removal effect is good, and it can be used only with compressed air. You can choose to install a foot switch or an infrared photoelectric sensor switch to control the airflow.
KP3008C-7T  3th generation ionizing air snake can generate a large amount of airflow with positive and negative charges, which can neutralize the charge on the object. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. The purpose of static electricity.
KP3008C-7T 3th generation ionizing air snake is used is used in industries such as electronic assembly lines, medical device manufacturing, semiconductor production and flat panel display manufacturing.


SECTION 2:FEATURES***************************************************************
1.Quickly eliminate static electricity.
2.Small size and space saving.
3.A regulator can be added to adjust the airflow size arbitrarily.
4.Infrared photoelectric sensor switch can be installed to avoid manual operation for customers to purchase.
5.The wind snake can be rotated to make the wind nozzle point to the target position, and the ion air flow can be directly blown to the target surface without manual operation.
6.The wind snake has a good grounding protection function.


SECTION 3:SPECIFICATIONS*******************************************************
Operate voltage 220V/50Hz or 110V/60Hz
Output voltage AC 4.6KV
Power        26W
Working distance       100-300mm
Ion balance   ≤|±35V|
Discharge time    ≤2S
Working temperature      0ºC-50ºC
Working humidity <70%
Noise     <70dB
Weight    3.0kg
Surface Stoving varnish
Use medium Clean comprssed air
Air supply connector Ф8mm(customized length)
Compressed air pressure 0.3-0.8Mpa
Airflow velocity 3-10m/S
Snake tube length 525mm
Power cord length 1.8M

SECTION 4:TEST  RESULT**********************************************************
Testing condition
Humidity:≤60%         Testing voltage:1KV-100V        Temperature:22ºC
Distance 300mm
Decay time Positive 0.8s
Negative 0.9s
Offset voltage ≤±50V

* The test result by ME268A comprehensive electrostatic tester shall prevail.
* Test according to IEC - 61340-5-1 A 6.
* Test data may change with the surrounding temperature and humidity.

SECTION 5:APPLICATION************************************************************
Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
SECTION 6:KAPPER NEW FACTORY*************************************
Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
SECTION 7:CERTIFICATES******************************************************
Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower
SECTION 8:KAPPER STYLE****************************************************
Kapper 3th Gneration Ionizing Air Snake Electrostatic Discharge Blower

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier